ABB ACS880-04 series AC Inverter for 200kW (270HP) 400V 3 Ph motor to 361A at high overload or 250kW (335HP) to 485A when Fan/Pump rated. Designed for cabinet installation, this module operates in VxF or Sensorless Vector as standard and full Closed-loop Flux Vector or Direct Torque Control (DTC) when an optional Encoder Feedback card is fitted. Converts fixed frequency Three Phase 400V input to variable frequency 400V to control the speed of a standard AC induction motor, permanent magnet synchronous motor, servo motor or synchronous reluctance motor.
Size R10: 377.9mm Wide x 505mm Deep x 1541mm High.
Enclosure Rating: IP00.
Weight: 161kg.
Overload: 150% x 60 seconds every 5 minutes (High Overload)
Overload: 110% x 60 seconds every 5 minutes (Fan/Pump rated)
Speed Control Range: 0-500Hz.
Braking: None (external braking unit optional)
Operator Keypad (Assistant Control Panel) with USB included as standard.
2 Analogue Inputs, 6 Digital Inputs, 2 Analogue Outputs, 2 Digital Inputs/Outputs, 1 Digital Input Interlock (DIIL), 3 Relay Contact Sets, terminals for RS-485/Modbus RTU communications or ABB Drive-to-drive (XD2D) link, terminals for dual channel SIL3 safe torque off (STO), 24V AC/DC input to power the control unit when the main supply is disconnected.
Input Current: 505A (nominal)
Input Voltage: 380-415V Three Phase +10% -15% at 50-60Hz ±5%
EMC Compliance: No EMC filter.
Cubicle mount.
Rated 40°C Ambient.
Supplied with wheels and rails for installation upright on the the cabinet bottom. Refer to manual for installation details and recommended cabinet.
Heat Loss at max output: 5.602kW
Manufacturer Part Number is ACS880-04-505A-3.